The short answer

Open cell spray foam is light, soft and lets water vapor pass through. Closed-cell foam is dense, rigid and, at the thickness its data sheet lists, stops water vapor. Both are polyurethane, both seal air leaks well, and neither is better in every building. They suit different jobs. PolyJacks sprays closed-cell only, so this page is an honest comparison from a firm that does not sell the other one.

For a steel building, closed-cell is the product that fits, and the reason is moisture on cold metal, covered below. For some other buildings, open-cell is the right product, and a section further down says which.

The numbers on this page come from one federal guide. That guide dates from 2009 and describes typical foams of that time, so these are typical values, and a real data sheet for a real product replaces every one of them. Our own product's sheet is on closed-cell spray foam insulation.

Open cell spray foam vs closed cell: the difference table

Source for every cell in this table: the U.S. Department of Energy Building America guide "Which Spray Foam Is Right For You?" (Steven Winter Associates, updated April 3, 2009). It is a federal guide for houses in several states. The foam's behavior (what a cell structure does to heat, air, vapor and water) is the same in a Kansas shop. What changes is which assembly it goes into.

PropertyOpen-cell (half-pound foam)Closed-cell (2-lb foam)
Nominal density0.5 lb per cubic foot2.0 lb per cubic foot
Share of closed cellsunder 10 percentover 90 percent
R-value per inch, agedabout 3.6about 6.1
Vapor permeance10 perms at 5 in thick (the guide says 5 to 10 at typical thickness)under 1 perm at 2 in thick
Is it a vapor retarder?No. A vapor retarder is 1.0 perm or lessYes, at typical applied thickness
Air permeanceAir-impermeable at typical thicknessAir-impermeable; the guide's test value is far smaller
Takes in liquid water?Yes: it can hold up to a third of its volumeNo: described as hydrophobic
Feel and strengthSoft, compressible; compressive strength under 2.0 psiRigid; compressive strength 22 psi
Expansion from liquidup to about 150 timesabout 35 to 50 times
Single-pass limitfull depth in one pass, generally up to 10 intypically 2 to 3 in per pass
Blowing agent (2009)mainly watermainly hydrofluorocarbons
Sound, wood-stud wall testSTC 37, NRC 70no data given
Flame spread and smokeunder 25, under 450under 25, under 450
What drives installed costlower, because each gallon of liquid expands furtherhigher, because more liquid goes into each cubic foot

A few of those rows deserve a plain reading.

R per inch is not R of the job. Aged values drift from fresh ones, which is the subject of aged R-value of spray foam. Closed-cell reaches a given R in a little more than half the thickness of open-cell. In a deep wood cavity, thickness is cheap and that matters little. In a steel building with shallow flanges, thickness is the limit and it matters a lot.

"Air-impermeable" and "vapor-impermeable" are different words. Both foams stop moving air at typical thicknesses. Only one stops moving vapor. People buy open cell spray foam for its air sealing and then expect it to behave as a vapor barrier too, and the table shows it does not.

The blowing agents have moved on since 2009. Current products use different agents from those the guide describes. The up-to-date story is on low-GWP HFO spray foam. Treat the guide's chemistry row as history.

The cost row is direction only. We publish no prices. The guide's cost figures are from 2009 and are not used here. What changes the number today is covered on what drives spray foam cost.

Why open-cell on cold steel lets moisture reach the panel

Steel is a thin skin with almost no resistance to heat, so on a cold night its inside face can sit below the dew point of the building's air. A reflective-insulation trade group's FAQ states the rule: condensation occurs on any surface at or below the dew point, and if indoor air with water vapor reaches a cold roof deck, condensation is likely (RIMA, Condensation FAQ). RIMA is a trade group for reflective products and the physics it states is general; we use it only for that.

Now put open-cell against the steel. At 5 inches it passes 5 to 10 perms in the guide's figures, and the guide says it can take in and hold liquid water. Damp inside air moves through the foam, reaches the cold panel and condenses on it, and the foam can hold the water there against the metal. Closed-cell, continuous and thick enough to count as a vapor retarder, keeps that air off the steel. The practical test is the thickness, and the method for it is on spray foam for metal buildings.

That is a general moisture argument, not a promise about any one building.

When open-cell is the right product

Open-cell wins in some cases, and a firm that sprays only closed-cell should say which. In the DOE guide's ratings, open-cell is rated preferred for a cold-climate wood-frame wall and acceptable for a sloped roof deck. Add its sound test values and you have the strongest cases:

CaseWhy open-cell fitsWhat the guide says must come with it
Wood-frame wall cavities in a cold climate (rated preferred)Reasonable R per inch and excellent air sealing in a deep cavity, nearly always sprayed to full depthInterior air sealing and an interior vapor retarder (paint can serve), and an exterior that lets moisture out
Sloped roof decks in cold-climate houses (rated acceptable)Gives full insulation at the roof deck and blocks airA vapor retarder over it unless the roof surface is itself moisture-tight, such as standing seam metal, and a barrier covering per the product
Sound control in a stud wallThe guide lists test values for it (STC 37 in a wood stud wall) and none for closed-cell; rain on a steel roof is a separate question on rain noise on a metal roofThe values apply to that tested wall, not to your building

Two honest conclusions. First, the guide is about low-rise houses, so its cases are wood-frame assemblies and do not carry over to a steel shop.

The other types of spray foam

The word "polyurethane foam insulation" covers all of the following. The guide says open-cell and closed-cell are chemically similar, a two-part spray from an isocyanate side and a resin side (DOE Building America guide, 2009). "Urethane foam" and "liquid foam" are other names for the same families. Beyond cell type, the split that matters is how the foam is delivered, and the EPA's page on product types lists three (EPA Safer Choice, Spray Polyurethane Foam Product Types, September 2020):

Delivery typeHow it worksWhat it is forWhat we use
Two-component, high pressureBoth sides pumped through heated hoses to a nozzle; the EPA page gives above 150 °F and 1,200 psiLarge insulation jobs, air sealing and roofing; professional installers onlyThis is the class of equipment we run: a proportioner and 200 ft of heated hose, with an employee crew
Two-component, low pressureSides combined at the site and sprayed as a stream or bead from small tanksAir sealing, adhesive uses and smaller jobsNo
One-component foam (cans)Pre-reacted foam that finishes curing with air moistureGaps from about half an inch to 3 in around windows, doors and similarNo

Two more terms you will meet:

  • Roofing foam. Closed-cell foam sprayed on the outside of a roof. The guide names low-slope roofs among the rigorous uses of closed-cell. That is a roofing trade, not interior insulation, and we do not do it on this service.
  • Injection foam. Foam put into a closed cavity through holes. We do not do it.

Density labels are used loosely. The guide calls the two main families "half-pound" foam and "2-lb" foam. "Low density" and "high density" in a quote only mean something when the data sheet's actual density is printed next to them.

FAQ

What is the difference between open cell and closed cell spray foam?

Closed-cell is denser, has more R per inch and resists water vapor; open-cell is lighter, softer and vapor-open. In the DOE guide's typical values, closed-cell has about R-6.1 per inch and open-cell about R-3.6. Open-cell also takes up water, which closed-cell does not. The table above sets out the other rows.

Is open cell or closed cell better for a metal building?

Closed-cell, because open-cell lets moist air reach the cold steel. At 5 inches, open-cell passes 5 to 10 perms in the DOE guide's figures, while closed-cell is under 1 perm at 2 inches. Condensation forms on any surface at or below the dew point (RIMA). The thickness that does the job is a data sheet question, covered on metal building spray foam.

Is open cell spray foam good for attics?

In ordinary houses it is a common choice, and the DOE guide rates it as acceptable to preferred in several roof-deck and attic cases, always with the moisture controls it names. That is education from the guide, not an offer. PolyJacks sprays closed-cell only, and inside buildings such as steel shops and barns. For a barn's roof or walls, see the options in metal building insulation compared.

Book a free on-site measurement

If you are unsure which product your building needs, the visit settles it. We measure the building, look at what is on the steel now, and you get a written estimate after the visit. If a different product suits your building better, we will say so. The visit is free; how it goes is on the free estimate visit.

Book a free on-site measurement

Pick "Spray foam insulation" on the booking form. We work within about 35 miles of Spring Hill, KS.

Spray foam insulation is a new PolyJacks service line run by its own crew and rig.

Who wrote this: PolyJacks spray foam team. How it was made: drafted with AI assistance from the sources below, then checked against each source.

Sources

  • U.S. Department of Energy, Building America, "Which Spray Foam Is Right For You?" (Consortium for Advanced Residential Buildings / Steven Winter Associates, updated April 3, 2009): www1.eere.energy.gov. Out-of-state federal guide for houses; the cell structure and its effects on air, vapor and water are the same in Kansas.
  • U.S. EPA, Safer Choice archive, "Spray Polyurethane Foam Product Types" (page dated September 2, 2020): archive.epa.gov
  • Reflective Insulation Manufacturers Association International, Condensation FAQ (trade group; physics only): rimainternational.org

Ready for a measurement?

Book a free on-site visit. We measure first, then quote in writing.

Spray foam insulation

Book a free on-site measurement

We measure the building first, then you get a written quote. Prefer to talk? Call (913) 713-7794.

Book a free on-site measurement

Free Estimate Call